HOME GENERATORS
Kohler automatic residential generator systems provide dependable protection during unexpected power outages. Kohler has produced home standby generators, residential emergency generators, and back up power devices since the 1920s. Kohler generators provide clean power for sensitive home electronics; fast power to get you up and running; and reliable backup power to ensure your life goes on even when the utility power doesn't.
A standby home generator keeps your power on during an outage. When utility power is interrupted, the ATS signals the generator to start and then quickly transfers the electrical loads from the failed utility to the generator. When utility power is restored, the ATS transfers the electrical loads back to the utility and shuts down the generator. It's installed outside your house (like an AC unit) and comes on automatically — whether you're home or away. All within seconds of a power outage.
Plus home generators run on propane or natural gas, so there's no refueling.
|
 |
 |
 |
 |
 |
Model Number |
8RESV |
10RESV |
12RESV |
14RESA |
20RESA |
Rated Power LP/NG (kW) |
8/7 |
10/9 |
12/11 |
14/12 |
20/18 |
Voltage @ 60 Hz |
120/240 |
120/240 |
120/240 |
120/240 |
120/240 |
Phase |
Single |
Single |
Single |
Single |
Single/Three |
Amps LPG/NG @ 240 V |
33.3/29.2 |
41.7/37.5 |
50/45.8 |
58.3/50 |
83.3/75 |
Automatic Transfer Switch and Load
Control Module (LCM) Compatibility |
RDT, RXT, LCM, RSB |
Engine/Alternator RPM |
3600 |
3600 |
3600 |
3600 |
3600 |
Engine |
597 cc |
725 cc |
725 cc |
725 cc |
999 cc |
Kohler SV620 |
Kohler KT725 |
Kohler KT725 |
KOHLER Command PRO OHV CH740 |
KOHLER Command PRO OHV CH1000 |
Single |
V-Twin |
V-Twin |
V-Twin |
V-Twin |
Fuel |
LPG/Natural Gas |
Engine Cooling |
Air |
Air |
Air |
Air |
Air |
Enclosure |
Powder Coated Steel |
Powder Coated Steel |
Powder Coated Steel |
Corrosion-Proof Polymer |
Corrosion-Proof Polymer |
Sound Output dBA at 23 Ft |
72* |
71* |
71* |
61* |
69* |
Dimensions (L x W x H) In |
28 x 30 x 32.4 |
28 x 30 x 32.4 |
28 x 30 x 32.4 |
48 x 26.2 x 29 |
48 x 26.2 x 29 |
Digital Voltage Regulation |
+/- 1.0% |
Specification Sheet |
8RESV |
10RESV |
12RESV |
14RESA |
20RESA |
RATINGS: Standby ratings apply to installations served by a reliable utility source. All single-phase units are rated at 1.0 power factor. The standby rating is applicable to variable loads with an average load factor of 80% for the duration of the power outage. No overload capacity is specified at this rating. Ratings are in accordance with ISO-3046/1, BS5514, AS2789 and DIN 6271. GENERAL GUIDELINES FOR DERATION: Altitude: Derate 4% per 305 m (1000 ft) elevation above 153 m (500 ft). Temperature: Derate 2% per 5.5˚C (10˚F) temperature increase above 16˚C (60˚F).
*Also available in three phase.
**Measured at 23 feet with no load.
|
 |
 |
 |
 |
 |
Model Number |
24RCL |
30RCL |
38RCLB |
48RCL |
60RCL |
Rated Power LP/NG (kW) |
24/21 |
30/30 |
38/38 |
48/48 |
59/57 |
Voltage @ 60 Hz |
120/240 |
120/240 |
120/240 |
120/240 |
120/240 |
Phase |
Single/Three |
Single/Three |
Single/Three |
Single/Three |
Single/Three |
Amps LPG/NG @ 240 V |
100/87 |
125/125 |
158/158 |
200/200 |
246/238 |
Automatic Transfer Switch and Load
Control Module (LCM) Compatibility |
RDT, RXT, LCM, RSB |
Engine/Alternator RPM |
1800 |
1800 |
1800 |
1800 |
1800 |
Engine |
2.2 L |
2.2 L |
2.2 L |
5.0 L |
5.7 L |
Kohler KG2204 |
Kohler KG2204 |
Kohler KG2204 |
General Motors Vortec |
General Motors Vortec |
In-line 4 |
In-line 4 |
In-line 4 |
V-8 |
V-8 |
Fuel |
LPG/Natural Gas |
LPG/Natural Gas |
LPG/Natural Gas |
LPG/Natural Gas |
LPG/Natural Gas |
Engine Cooling |
Liquid |
Liquid |
Liquid |
Liquid |
Liquid |
Enclosure |
Corrosion-Resistant Aluminum |
Corrosion-Resistant Aluminum |
Corrosion-Resistant Aluminum |
Corrosion-Resistant Aluminum |
Corrosion-Resistant Aluminum |
Sound Output dBA at 23 Ft |
61* |
61* |
61* |
61* |
61* |
Dimensions (L x W x H) In |
74 x 32.9 x 45.1 |
74 x 32.9 x 45.1 |
90 x 33.5 x 45.1 |
90 x 33.5 x 45.1 | 89.8 x 32.9 x 45.2 |
Digital Voltage Regulation |
+/- 1.0% |
Specification Sheet |
24RCL |
30RCL |
38RCLB |
48RCL |
60RCL |
RATINGS: Standby ratings apply to installations served by a reliable utility source. All single-phase units are rated at 1.0 power factor. The standby rating is applicable to variable loads with an average load factor of 80% for the duration of the power outage. No overload capacity is specified at this rating. Ratings are in accordance with ISO-3046/1, BS5514, AS2789 and DIN 6271. GENERAL GUIDELINES FOR DERATION: Altitude: Derate 4% per 305 m (1000 ft) elevation above 153 m (500 ft). Temperature: Derate 2% per 5.5˚C (10˚F) temperature increase above 16˚C (60˚F).
*Measured at 23 feet with no load.